Søk etter VIN / Frame, merke, modell, kjøretøytype, aggregatnavn eller artikkelnummer for en hvilken som helst olje:
Søkeresultater for «Fives Cincinnati P-38»
RAVENOL Hydraulikoel TS 32 (HLP)
For hydraulikk
Hydraulisk olje for termisk belastede hydrauliske systemer, med høytrykkspumper, samt for vedlikehold av små mekanismer og som arbeidsvæske i lukkede systemer.
Oppfyller kravene:
AFNOR NFE 48-603 HM, Bosch Rexroth RE 90220, Cetop RP 91H HM, Danieli Hydraulics, Eaton Vickers I-286-S, FZG Test A 8,3/90, Fives Cincinnati P-38, Fives Cincinnati P-68, GB 111118.1 L-HM, GM LH-02-1-04, GM LS-2, ISO 11158 HM, JCMAS HK, MIL-PRF-17672 E, Müller , Parker Denison HF-0, Parker Denison HF-1, Parker Denison HF-2, SAE MS 1004 HM, SEB 181.222, Sauer-Danfoss 520L0463, U.S. Steel 126, U.S. Steel 127, U.S. Steel 136, VDMA 24318, Vickers M-2950-S, Vickers Pumpentest
Viskositet: 32W
- Tilgjengelige pakningsstørrelser
- Full beskrivelse
- Produktparametere
Volum:
1 l
Artikkelnummer:
1323104-001
1323104-001-01-999
Kode:
4014835759312
Volum:
5 l
Artikkelnummer:
1323104-005
1323104-005-01-999
Kode:
4014835759350
Volum:
20 l
Artikkelnummer:
1323104-020
1323104-020-01-999
Kode:
4014835759329
Volum:
20 l, ecobox
Artikkelnummer:
1323104-B20
Volum:
60 l
Artikkelnummer:
1323104-060
1323104-060-01-999
Kode:
4014835759367
Volum:
208 l
Artikkelnummer:
1323104-208
1323104-208-01-999
Kode:
4014835759381
Volum:
1 000 l
Artikkelnummer:
1323104-700
RAVENOL Hydraulikoel TS 32 (HLP) – mineralbasert hydraulikkolje av HLP-klasse med tilsetning av høyeffektive additiver. Optimalt legert, gir forlenget skifteintervall og et bredt spekter av driftstemperaturer i ulike industrielle bruksområder. Garantérer gode viskositets-temperatur-egenskaper, høy aldringsbestandighet og pålitelig korrosjonsbeskyttelse. Takket være en spesiell additivpakke gir den beskyttelse mot slitasje ved ekstreme belastninger.
Bruksområde:
RAVENOL Hydraulikoel TS 32 (HLP) er universelt anvendelig i alle hydrauliske systemer. Anbefales for termisk belastede hydrauliske systemer, med høytrykkspumper, samt for vedlikehold av små mekanismer og som arbeidsvæske i lukkede systemer.
Bruksområde Hydraulikkolje TS 32 (HLP) gir:
- Utmerkede viskositets-temperatur-egenskaper
- Utmerket slitasjebeskyttelse
- Utmerket korrosjonsbeskyttelse
- Nøytral oppførsel overfor tetningsmaterialer
- Forlenget oljeskifteintervall
- Utmerket aldringsbestandighet
| Parameter | Måleenhet | Verdi | Tester | |
|---|---|---|---|---|
| Viskositet | 32W |
32W
|
||
| Type | Mineral |
Mineral
|
||
| ASTM | D6158 |
D6158
|
||
| Oppfyller kravene | AFNOR NFE 48-603 HM, Bosch Rexroth RE 90220, Cetop RP 91H HM, Danieli Hydraulics, Eaton Vickers I-286-S, FZG Test A 8,3/90, Fives Cincinnati P-38, Fives Cincinnati P-68, GB 111118.1 L-HM, GM LH-02-1-04, GM LS-2, ISO 11158 HM, JCMAS HK, MIL-PRF-17672 E, Müller , Parker Denison HF-0, Parker Denison HF-1, Parker Denison HF-2, SAE MS 1004 HM, SEB 181.222, Sauer-Danfoss 520L0463, U.S. Steel 126, U.S. Steel 127, U.S. Steel 136, VDMA 24318, Vickers M-2950-S, Vickers Pumpentest |
AFNOR NFE 48-603 HM, Bosch Rexroth RE 90220, Cetop RP 91H HM, Danieli Hydraulics, Eaton Vickers I-286-S, FZG Test A 8,3/90, Fives Cincinnati P-38, Fives Cincinnati P-68, GB 111118.1 L-HM, GM LH-02-1-04, GM LS-2, ISO 11158 HM, JCMAS HK, MIL-PRF-17672 E, Müller , Parker Denison HF-0, Parker Denison HF-1, Parker Denison HF-2, SAE MS 1004 HM, SEB 181.222, Sauer-Danfoss 520L0463, U.S. Steel 126, U.S. Steel 127, U.S. Steel 136, VDMA 24318, Vickers M-2950-S, Vickers Pumpentest
|
||
| Oppfyller spesifikasjonene | DIN 51524-2, ISO 6743-4 HM |
DIN 51524-2, ISO 6743-4 HM
|
||
| Passer for | Atos, Metso |
Atos, Metso
|
||
| Tetthet ved 20 °C | g/cm³ | 848 | EN ISO 12185 |
848
g/cm³
EN ISO 12185
|
| Farge | Lys gul | visuell |
Lys gul
visuell
|
|
| Viskositet ved 100 °C | mm²/s | 5.8 | DIN 51562-1 |
5.8
mm²/s
DIN 51562-1
|
| Viskositet ved 40 °C | mm²/s | 32.1 | DIN 51562-1 |
32.1
mm²/s
DIN 51562-1
|
| Viskositetsindeks VI | 123 | DIN ISO 2909 |
123
DIN ISO 2909
|
|
| Godkjenninger | AFNOR NFE 48-603 HM, Bosch Rexroth RE 90220, Cetop RP 91H HM, DIN 51524-2, Danieli Hydraulics, Eaton Vickers I-286-S, FZG Test A 8,3/90, Fives Cincinnati P-38, Fives Cincinnati P-68, GB 111118.1 L-HM, GM LH-02-1-04, GM LS-2, ISO 11158 HM, ISO 6743-4 HM, JCMAS HK, MIL-PRF-17672 E, Müller , Parker Denison HF-0, Parker Denison HF-1, Parker Denison HF-2, SAE MS 1004 HM, SEB 181.222, Sauer-Danfoss 520L0463, U.S. Steel 126, U.S. Steel 127, U.S. Steel 136, VDMA 24318, Vickers M-2950-S, Vickers Pumpentest |
AFNOR NFE 48-603 HM, Bosch Rexroth RE 90220, Cetop RP 91H HM, DIN 51524-2, Danieli Hydraulics, Eaton Vickers I-286-S, FZG Test A 8,3/90, Fives Cincinnati P-38, Fives Cincinnati P-68, GB 111118.1 L-HM, GM LH-02-1-04, GM LS-2, ISO 11158 HM, ISO 6743-4 HM, JCMAS HK, MIL-PRF-17672 E, Müller , Parker Denison HF-0, Parker Denison HF-1, Parker Denison HF-2, SAE MS 1004 HM, SEB 181.222, Sauer-Danfoss 520L0463, U.S. Steel 126, U.S. Steel 127, U.S. Steel 136, VDMA 24318, Vickers M-2950-S, Vickers Pumpentest
|
||
| Anbefalinger | AFNOR NFE 48-603 HM, ASTM D6158, Atos, Bosch Rexroth RE 90220, CETOP RP 91H HM, Danieli Hydraulics, Eaton Vickers I-286-S, FZG-Test A 8,3/90, Fives Cincinnati P-38, Fives Cincinnati P-68, GB 111118.1 L-HM (conventional), GM LH-02-1-04, GM LS-2, ISO 11158 HM, JCMAS HK, M-2950-S, MIL-PRF-17672 E, Metso, Müller Weingarten, Parker Denison HF-0, Parker Denison HF-1, Parker Dension HF-2, SAE MS1004 HM, SEB 181.222, Sauer-Danfoss 520L0463, US Steel 126, US Steel 127, US Steel 136, VDMA 24318, Vickers-Pumpentest |
AFNOR NFE 48-603 HM, ASTM D6158, Atos, Bosch Rexroth RE 90220, CETOP RP 91H HM, Danieli Hydraulics, Eaton Vickers I-286-S, FZG-Test A 8,3/90, Fives Cincinnati P-38, Fives Cincinnati P-68, GB 111118.1 L-HM (conventional), GM LH-02-1-04, GM LS-2, ISO 11158 HM, JCMAS HK, M-2950-S, MIL-PRF-17672 E, Metso, Müller Weingarten, Parker Denison HF-0, Parker Denison HF-1, Parker Dension HF-2, SAE MS1004 HM, SEB 181.222, Sauer-Danfoss 520L0463, US Steel 126, US Steel 127, US Steel 136, VDMA 24318, Vickers-Pumpentest
|
RAVENOL Hydraulikoel TS AF 32
For hydraulikk
Oppfyller kravene:
Eaton Vickers I-286-S, Eaton Vickers M-2950-S, FZG Test A 8,3/90, Fives Cincinnati P-38, Fives Cincinnati P-68, GM LH-03-1-04, MAN N 698, Müller , Parker Denison HF-0, Parker Denison HF-1, Parker Denison HF-2, SEB 181.222, SEB 181.226, Thyssen TH-N256-142, Timken-Test DIN E 51434, Vickers Pumpentest
Viskositet: 32W
- Tilgjengelige pakningsstørrelser
- Produktparametere
Volum:
20 l
Artikkelnummer:
1323124-020
Volum:
20 l, ecobox
Artikkelnummer:
1323124-B20
Volum:
60 l
Artikkelnummer:
1323124-060
Volum:
208 l
Artikkelnummer:
1323124-208
1323124-208-01-999
Kode:
4014835759787
| Parameter | Måleenhet | Verdi | Tester | |
|---|---|---|---|---|
| Viskositet | 32W |
32W
|
||
| Type | Mineral |
Mineral
|
||
| Oppfyller kravene | Eaton Vickers I-286-S, Eaton Vickers M-2950-S, FZG Test A 8,3/90, Fives Cincinnati P-38, Fives Cincinnati P-68, GM LH-03-1-04, MAN N 698, Müller , Parker Denison HF-0, Parker Denison HF-1, Parker Denison HF-2, SEB 181.222, SEB 181.226, Thyssen TH-N256-142, Timken-Test DIN E 51434, Vickers Pumpentest |
Eaton Vickers I-286-S, Eaton Vickers M-2950-S, FZG Test A 8,3/90, Fives Cincinnati P-38, Fives Cincinnati P-68, GM LH-03-1-04, MAN N 698, Müller , Parker Denison HF-0, Parker Denison HF-1, Parker Denison HF-2, SEB 181.222, SEB 181.226, Thyssen TH-N256-142, Timken-Test DIN E 51434, Vickers Pumpentest
|
||
| Oppfyller spesifikasjonene | AFNOR NF E 48-603 HM, DIN 51524-2, GB 111118.1 L-HM, ISO 11158, ISO 6743-4 HM, MS1004 HM, SAE MS 1004 HM, U.S. Steel 127, U.S. Steel 136 |
AFNOR NF E 48-603 HM, DIN 51524-2, GB 111118.1 L-HM, ISO 11158, ISO 6743-4 HM, MS1004 HM, SAE MS 1004 HM, U.S. Steel 127, U.S. Steel 136
|
||
| Tetthet ved 20 °C | g/cm³ | 855 | EN ISO 12185 |
855
g/cm³
EN ISO 12185
|
| Farge | gul | visuell |
gul
visuell
|
|
| Viskositet ved 100 °C | mm²/s | 5.8 | DIN 51562-1 |
5.8
mm²/s
DIN 51562-1
|
| Viskositet ved 40 °C | mm²/s | 32.2 | DIN 51562-1 |
32.2
mm²/s
DIN 51562-1
|
| Viskositetsindeks VI | 124 | DIN ISO 2909 |
124
DIN ISO 2909
|
|
| Godkjenninger | AFNOR NF E 48-603 HM, DIN 51524-2, Eaton Vickers I-286-S, Eaton Vickers M-2950-S, FZG Test A 8,3/90, Fives Cincinnati P-38, Fives Cincinnati P-68, GB 111118.1 L-HM, GM LH-03-1-04, ISO 11158, ISO 6743-4 HM, MAN N 698, MS1004 HM, Müller , Parker Denison HF-0, Parker Denison HF-1, Parker Denison HF-2, SAE MS 1004 HM, SEB 181.222, SEB 181.226, Thyssen TH-N256-142, Timken-Test DIN E 51434, U.S. Steel 127, U.S. Steel 136, Vickers Pumpentest |
AFNOR NF E 48-603 HM, DIN 51524-2, Eaton Vickers I-286-S, Eaton Vickers M-2950-S, FZG Test A 8,3/90, Fives Cincinnati P-38, Fives Cincinnati P-68, GB 111118.1 L-HM, GM LH-03-1-04, ISO 11158, ISO 6743-4 HM, MAN N 698, MS1004 HM, Müller , Parker Denison HF-0, Parker Denison HF-1, Parker Denison HF-2, SAE MS 1004 HM, SEB 181.222, SEB 181.226, Thyssen TH-N256-142, Timken-Test DIN E 51434, U.S. Steel 127, U.S. Steel 136, Vickers Pumpentest
|
||
| Anbefalinger | Eaton Vickers I-286-S, Eaton Vickers M-2950-S, FZG-Test A 8,3/90, Fives Cincinnati P-38, Fives Cincinnati P-68, GM LH-03-1-04, MAN N 698, Müller Weingarten, Parker Denison HF-0, Parker Denison HF-1, Parker Dension HF-2, SEB 181.222, SEB 181.226, Thyssen TH-N256-142, Timken-Test nach DIN E 51434, Vickers-Pumpentest |
Eaton Vickers I-286-S, Eaton Vickers M-2950-S, FZG-Test A 8,3/90, Fives Cincinnati P-38, Fives Cincinnati P-68, GM LH-03-1-04, MAN N 698, Müller Weingarten, Parker Denison HF-0, Parker Denison HF-1, Parker Dension HF-2, SEB 181.222, SEB 181.226, Thyssen TH-N256-142, Timken-Test nach DIN E 51434, Vickers-Pumpentest
|