Search by VIN, make, model, vehicle type, unit name, or by article number of any oil:
Application NoteRAVENOL Vakuumpumpenöl ISO VG 46 is suitable for the lubrication of vacuum pumps (rotary vane pumps, diffusion pumps, turbo pumps), where mineral oils are required, as well as for mist lubrication and crankcase.
Compliance with the requirements:
Alcatel 100, Alcatel 119, Alcatel 120, Balzers P3, Becker Vakuumpumpen, Beckmann 19, BUSCH VM, BUSCH VMH, Fisherbrand 19, Hyvac 93055, Kinney Type A, Leybold-Heraeus 175, PVR Rotant, SAVANT SPO-1, Ulvac 100
SAE: 46
- Available packaging
- Product parameters
Volume:
1 L
vendor code:
1330705-001
Volume:
5 L
vendor code:
1330705-005
Volume:
20 L, ecobox
vendor code:
1330705-B20
Volume:
60 L
vendor code:
1330705-060
Volume:
208 L
vendor code:
1330705-208
Application Note
RAVENOL Vakuumpumpenöl ISO VG 46 is suitable for the lubrication of vacuum pumps (rotary vane pumps, diffusion pumps, turbo pumps), where mineral oils are required, as well as for mist lubrication and crankcase.
RAVENOL Vakuumpumpenöl ISO VG 46 oil can be used very well for the lubrication of crankcases.
Characteristics
- High performance level
- Very good viscosity-temperature behavior
- High resistance to aging
- Excellent wear protection
- Reliable corrosion protection
- Neutral to seal materials
Parameter | Unit | Value | Audit | |
---|---|---|---|---|
Brand | RAVENOL |
RAVENOL
|
||
SAE | 46 |
46
|
||
Type | Mineral |
Mineral
|
||
Recomendations | Alcatel 100, Alcatel 119, Alcatel 120, Balzers P3, Becker Vakuumpumpen, Beckmann 19, BUSCH VM, BUSCH VMH, Fisherbrand 19, Hyvac 93055, Kinney Type A, Leybold-Heraeus 175, PVR Rotant, SAVANT SPO-1, Ulvac 100 |
Alcatel 100, Alcatel 119, Alcatel 120, Balzers P3, Becker Vakuumpumpen, Beckmann 19, BUSCH VM, BUSCH VMH, Fisherbrand 19, Hyvac 93055, Kinney Type A, Leybold-Heraeus 175, PVR Rotant, SAVANT SPO-1, Ulvac 100
|
||
specification | DIN 51506 VC, ISO 6743-3 DVA, ISO 6743-3 DVC |
DIN 51506 VC, ISO 6743-3 DVA, ISO 6743-3 DVC
|
||
Compliant products | Edwards Ultragrade 19 |
Edwards Ultragrade 19
|
||
Density at 20 °C | kg/m³ | 854 | EN ISO 12185 |
854
kg/m³
EN ISO 12185
|
Color | light yellow | visual |
light yellow
visual
|
|
Viscosity at 100 °C | mm²/s | 7.4 | DIN 51562-1 |
7.4
mm²/s
DIN 51562-1
|
Viscosity at 40 °C | mm²/s | 47.2 | DIN 51562-1 |
47.2
mm²/s
DIN 51562-1
|
Viscosity Index VI | 121 | DIN ISO 2909 |
121
DIN ISO 2909
|
|
Pourpoint | °C | -36 | DIN ISO 3016 |
-36
°C
DIN ISO 3016
|
Flashpoint | °C | 244 | DIN EN ISO 2592 |
244
°C
DIN EN ISO 2592
|
Carbon residue Conradson | % | 0.05 | DIN 51551 |
0.05
%
DIN 51551
|
Boiling point at 0,01 bar | 112 | DIN 51757 |
112
DIN 51757
|
|
Vapor pressure | bar | 3 x 10 ‾3 | DIN 51757 |
3 x 10 ‾3
bar
DIN 51757
|
Approvals | Alcatel 100, Alcatel 119, Alcatel 120, Balzers P3, Becker Vakuumpumpen, Beckmann 19, BUSCH VM, BUSCH VMH, DIN 51506 VC, Fisherbrand 19, Hyvac 93055, ISO 6743-3 DVA, ISO 6743-3 DVC, Kinney Type A, Leybold-Heraeus 175, PVR Rotant, SAVANT SPO-1, Ulvac 100 |
Alcatel 100, Alcatel 119, Alcatel 120, Balzers P3, Becker Vakuumpumpen, Beckmann 19, BUSCH VM, BUSCH VMH, DIN 51506 VC, Fisherbrand 19, Hyvac 93055, ISO 6743-3 DVA, ISO 6743-3 DVC, Kinney Type A, Leybold-Heraeus 175, PVR Rotant, SAVANT SPO-1, Ulvac 100
|
Application NoteRAVENOL Vakuumpumpenoel ISO VG 32 is suitable for the lubrication of vacuum pumps (rotary vane pumps, diffusion pumps, turbo pumps), where mineral oils are required, as well as for mist lubrication and crankcase.
Compliance with the requirements:
Alcatel 100, Alcatel 119, Alcatel 120, Balzers P3, Becker Vakuumpumpen, Beckmann 19, BUSCH VM, BUSCH VMH, DIN 51506 VC, Fisherbrand 19, Hyvac 93055, ISO 6743-3 DVA, ISO DVC, Kinney Type A, Leybold-Heraeus 175, PVR Rotant, SAVANT SPO-1, Ulvac 100
SAE: 32W
- Available packaging
- Product parameters
Volume:
1 L
vendor code:
1330704-001
Volume:
5 L
vendor code:
1330704-005
Volume:
10 L
vendor code:
1330704-010
Volume:
20 L, ecobox
vendor code:
1330704-B20
Volume:
60 L
vendor code:
1330704-060
Volume:
208 L
vendor code:
1330704-208
Application Note
RAVENOL Vakuumpumpenoel ISO VG 32 is suitable for the lubrication of vacuum pumps (rotary vane pumps, diffusion pumps, turbo pumps), where mineral oils are required, as well as for mist lubrication and crankcase.
RAVENOL Vakuumpumpenoel ISO VG 32 oil can be used very well for the lubrication of crankcases.
Characteristics
- High performance level
- Very good viscosity-temperature behavior
- High resistance to aging
- Excellent wear protection
- Reliable corrosion protection
- Neutral to seal materials
Parameter | Unit | Value | Audit | |
---|---|---|---|---|
Brand | RAVENOL |
RAVENOL
|
||
SAE | 32W |
32W
|
||
Type | Mineral |
Mineral
|
||
Recomendations | Alcatel 100, Alcatel 119, Alcatel 120, Balzers P3, Becker Vakuumpumpen, Beckmann 19, BUSCH VM, BUSCH VMH, DIN 51506 VC, Fisherbrand 19, Hyvac 93055, ISO 6743-3 DVA, ISO DVC, Kinney Type A, Leybold-Heraeus 175, PVR Rotant, SAVANT SPO-1, Ulvac 100 |
Alcatel 100, Alcatel 119, Alcatel 120, Balzers P3, Becker Vakuumpumpen, Beckmann 19, BUSCH VM, BUSCH VMH, DIN 51506 VC, Fisherbrand 19, Hyvac 93055, ISO 6743-3 DVA, ISO DVC, Kinney Type A, Leybold-Heraeus 175, PVR Rotant, SAVANT SPO-1, Ulvac 100
|
||
Compliant products | Edwards Ultragrade 19 |
Edwards Ultragrade 19
|
||
Density at 20 °C | kg/m³ | 848 | EN ISO 12185 |
848
kg/m³
EN ISO 12185
|
Color | light yellow | visual |
light yellow
visual
|
|
Viscosity at 100 °C | mm²/s | 5.8 | DIN 51562-1 |
5.8
mm²/s
DIN 51562-1
|
Viscosity at 40 °C | mm²/s | 32.1 | DIN 51562-1 |
32.1
mm²/s
DIN 51562-1
|
Viscosity Index VI | 123 | DIN ISO 2909 |
123
DIN ISO 2909
|
|
Pourpoint | °C | -30 | DIN ISO 3016 |
-30
°C
DIN ISO 3016
|
Flashpoint | °C | 224 | DIN EN ISO 2592 |
224
°C
DIN EN ISO 2592
|
FZG-Test A/8.3/90 Damage loading step | %wt. | 12 | DIN 51354/2 |
12
%wt.
DIN 51354/2
|
Approvals | Alcatel 100, Alcatel 119, Alcatel 120, Balzers P3, Becker Vakuumpumpen, Beckmann 19, BUSCH VM, BUSCH VMH, DIN 51506 VC, Fisherbrand 19, Hyvac 93055, ISO 6743-3 DVA, ISO DVC, Kinney Type A, Leybold-Heraeus 175, PVR Rotant, SAVANT SPO-1, Ulvac 100 |
Alcatel 100, Alcatel 119, Alcatel 120, Balzers P3, Becker Vakuumpumpen, Beckmann 19, BUSCH VM, BUSCH VMH, DIN 51506 VC, Fisherbrand 19, Hyvac 93055, ISO 6743-3 DVA, ISO DVC, Kinney Type A, Leybold-Heraeus 175, PVR Rotant, SAVANT SPO-1, Ulvac 100
|